Related Question
The magnitude of earth fault current for a given fault position within a winding demands upon the winding connections and method of neutral grounding.
Earth fault protection for an electric motor is provide by instantaneous relay having a setting of approximately 30% of motor rated current in the residual circuits of two CTs and with ground wire.
For t = 0 in RC circuit,
After t = 0+ condition, capacitor is behave as short circuit.
Voltage across the it 0.
At final time,
Capacitor is behave as open circuit, voltage across the capacitor at final time is equal to 15 V.
Capacitor opposes the change of voltage.
Equation is given by:
Efficiency = (F.F*Voc*Isc)/Pin
= (0.6*3.5*0.7)/10
= 0.14702
% efficiency = 14.7 %
Rotor frequency, f_r = s*f_s
s = 2/50
s = 0.04
Ns = 120f/P
Ns = 1500 rpm
s = (Ns - Nr)/Ns
Nr = Ns(1 - s)
Nr = 1500*(1 - 0.04)
Nr = 1440 rpm