When neutral disconnected Lamp are in series connection,
So, for series connection current is same for both Lamp,
Resistance of Lamp (L1) = (230)²/P
= (230)²/100
= 529 ohm
Resistance of lamp (L2) = (230)²/150
= 352.67 ohm
So, current through the lamp = E/(R1 + R2)
= 400/(529 + 352.67)
= 0.454 A
Voltage across lamp (L1) = I*R1
= 0.454*230
= 240 V
Equation is given by:
Efficiency = (F.F*Voc*Isc)/Pin
= (0.6*3.5*0.7)/10
= 0.14702
% efficiency = 14.7 %
In bias differential protection for transformer,
There are two basic settings required to setup the percentage biased differential protection.
1. Minimum pickup
2. The slope.
The minimum pick-up covers the transformer magnetizing current typically 1-4% of transformer rating.
A pick up of 0.2 to 0.3 times the TAP is recommended for general cases.
The slope is defined by determining the potential sources of differential current.